Product instructions for use
1.Preparation before starting: check that the bearing and moveable joints are sufficiently lubricated and there is no jamming; confirm that the fastener is fastened and there is no debris in the body; check that the gap between the counterattack liner and the rotor plate hammer meets the standard; rotate the rotor by hand to confirm that the operation is normal and there is no bruise.
2. Start-up operation: start after checking that the whole machine is correct; if there is any abnormality after starting, stop immediately to troubleshoot the fault, eliminate it and restart.
3. Feeding requirements: the feeding device should be used for uniform and continuous feeding, and the materials should be distributed throughout the working length of the rotor to avoid material blockage and stuffing; the feeding device is electrically interlocked with the crusher, and the conveyor belt will automatically stop and break the material when the equipment is overloaded.
4. Discharge gap adjustment: Through the operation of the adjustment device, the side wall door of the frame can be opened to observe the gap; the first counterattack frame is adjusted by screwing the M56 nut, and the second counterattack frame and the equaliser plate are adjusted by screwing the M48 nut (the screw sleeve needs to be loosened before adjustment, and tightened after adjustment); the adjustment must be carried out after shutdown.
5. Shutdown operation: Stop feeding before shutting down, and then cut off the power supply.